USED Liebert 75 kva UPS Model AP366 w/ two battery cabinets for sale in Everglades National Park, Florida

$12,000

I have for sale a working Liebert 75 kVa [Model AP366] UPS (Uninterrupted Power Source) that was pulled from a working environment (hospital) and has two battery cabinets that can carry 30 batteries each. Batteries DO NOT come with either of the cabinets. This would be a great economical unit for a company OR a great unit to export internationally for use in any large business, hospital, or government building.
I am asking only $12,000 ... PRICE IS NEGOTIABLE
Please call or text for serious buyers only 305''.
To see what else I am selling on Americanlisted type "pickin post" in the search.
pickin' post
Technical Specs
Input
Voltage 208, 240, 480 or 600 VAC, 60 Hz,
3 or 4-Wire plus ground Voltage Range +10%, -25%
Frequency Range 60 Hz 5%
Current Limit 125% of full load
input current Current Walk-In 20 seconds to full load
Surge Protection Sustains input surges
without damage, per criteria listed in ANSI C62.41-1980 (IEEE 587)
Output
Voltage 208, 240, 480 or 600 VAC, 60 Hz, 3 or 4-Wire plus ground
Voltage Regulation +-1% for balanced load
Voltage Unbalance +-1% for balanced load,
2% for 50% unbalanced load, +-5% for 100% unbalanced load
Voltage Adjustment Range +-5%
Frequency Regulation 60 Hz +-0.1%
Load Power Factor Range 0.9 Leading to 0.5 Lagging
Power Rating Rated kVA at 0.8 lagging power factor
Harmonic Distortion 5% maximum total for linear loads. 3% maximum for single harmonics
Phase Displacement 120 1 for balanced load. 120 +- 3 degrees for unbalanced load.
Transient Response +-1% for loss or return of input power. +-4% for 20% step load or a manual transfer of 100% load. +-5% for 30% step load. +-8% for 50% step load.
Transient Recovery Time To within 1% of output voltage within 50 milliseconds
Overload Capability 125% for 10 minutes. 150% for 30 seconds.
Fault Clearing Current 300% subcycle
Physical
Cabinet NEMA Type 1 freestanding. Provided with casters and leveling feet.
Cooling Forced air. Redundant fans
Cable Entry Top or bottom
Access Front access only
Environmental
Operating Temperature 32-104 degrees F (0-40 degrees C) for UPS; 68-86 degrees F (20-30 degrees C) for battery
Non-Operating Temperature -4 deg F to 158 degrees F (-20 degrees C to 70 degrees C)
For battery, check manufacturer's recommendations
Relative Humidity 0 to 95% non-condensing
Altitude Up to 2000 meters. Derated for higher elevations
Audible Noise Level 65 dBA measured at 1 meter from the UPS